701.A. PURPOSE. This district is intended for light industrial businesses which are consistent with the capacity and availability of public and private utility services, and which do not require large amounts of land, generate large amounts of traffic, or create environmental problems in the way of odor, smoke, dust, glare, vibration or sound. This district is generally compatible with the “Commercial Mixed Use” and “Industrial” designations on the Official Land Use Map adopted in the City of Haysville Comprehensive Plan.
701.B. USE STANDARDS. The permitted and conditional uses allowed in this district are listed in TABLE 404.D, in accordance with SECTION 404.
701.C. DIMENSIONAL STANDARDS. The following standards shall apply to all principal structures in this district as listed in TABLE 701.C, in accordance with SECTION 405. See SECTION 407 for the dimensional standards for accessory structures.
Table 701.C. LI Dimensional Standards (in feet, unless otherwise noted).
|
Minimum lot area (sq. ft.) |
Minimum lot dimensions |
Minimum setback requirements |
Maximum building height |
||||
|
Width |
Depth |
Front yard |
Side yard |
Street yard |
Rear yard |
||
|
10,000 |
60 |
90 |
35 |
101 |
35 |
20 |
None |
1. If zero lot line development is allowed, or any portion of the building is more than 150 feet from a street, dedicated fire lanes shall be provided in the rear on at least two sides of the building.
701.D. PARKING REGULATIONS. See APPENDIX E-500.
701.E. LANDSCAPING REGULATIONS. See APPENDIX E-501.
701.F. SPECIAL LI DISTRICT REGULATIONS. The following special regulations shall apply to all property in the LI District, except as otherwise allowed or approved in accordance with these regulations.
1. No outdoor operations, display, or storage is permitted within the front yard, except as provided for below:
a. Required and accessory customer and employee vehicle parking and parking for vehicles used in conjunction with the business occupying the zoning lot is permitted in the front yard.
b. If the principal use of the lot is the sales or rental of vehicles or equipment, the display of such vehicles or equipment may be located on hard surface areas within the front yard.
c. Outdoor display and storage may be allowed in the front yard if items are stored immediately adjacent to the principal structure.
2. All items stored outdoors must be kept on an all-weather or hard surface.
3. All items stored outdoors, excluding those permitted by SECTION 701.F.1, shall not be visible from ground level view in any adjacent lot that is a lesser zoning district or from ground level view of any adjacent collector or arterial street.
4. Operations or products must not be objectionable due to odor, dust, smoke, noise, vibration, or other similar causes.
5. Any illumination shall be so arranged as to reflect the light away from adjoining premises and shall be in conformance with CHAPTER 8, ARTICLE 8 of the City Code.
702.A. PURPOSE. This district is intended for uses that have the potential of generating limited environmental impact, including but not specifically limited to the creation of odor, smoke, dust, glare, vibration, noise, and the use of dangerous and/or hazardous materials. This district is generally compatible with the “Industrial” designations on the Official Land Use Map adopted in the City of Haysville Comprehensive Plan.
702.B. USE STANDARDS. The permitted and conditional uses allowed in this district are listed in TABLE 404.D, in accordance with SECTION 404.
702.C. DIMENSIONAL STANDARDS. The following standards shall apply to all principal structures in this district as listed in TABLE 702.C, in accordance with SECTION 405. See SECTION 407 for the dimensional standards for accessory structures.
Table 702.C. HI Dimensional Standards (in feet, unless otherwise noted).
|
Minimum lot area (sq. ft.) |
Minimum lot dimensions |
Minimum setback requirements |
Maximum building height |
||||
|
Width |
Depth |
Front yard |
Side yard |
Street yard |
Rear yard |
||
|
10,000 |
100 |
100 |
35 |
01 |
35 |
02 |
None |
1. If a side yard is provided, a setback of not less than 5 feet shall be provided.
2. If a rear yard is provided, a setback of not less than 5 feet shall be provided. Additionally, if any portion of the building is more than 150 feet from a street, dedicated fire lanes shall be provided in the rear yard on at least two sides of the building.
702.D. PARKING REGULATIONS. See APPENDIX E-500.
702.E. LANDSCAPING REGULATIONS. See APPENDIX E-501.
702.F. HI DISTRICT SPECIAL REGULATIONS. The following special regulations shall apply to all property in the HI District, except as allowed or approved in accordance with these regulations.
1. No outdoor operations, display, or storage is permitted within the front yard, except as provided for below:
a. Required and accessory customer and employee vehicle parking and parking for vehicles used in conjunction with the business occupying the zoning lot is permitted in the front yard.
b. If the principal use of the lot is the sales or rental of vehicles or equipment, the display of such vehicles or equipment may be located on hard surface areas within the front yard.
c. Outdoor display and storage may be allowed in the front yard if items are stored immediately adjacent to the principal structure.
2. All items stored outdoors shall be kept on an all-weather or hard surface.
3. All items stored outdoors, excluding those permitted by SECTION 702.F.1, shall not be visible from ground level view in any adjacent lot that is a lesser zoning district or from ground level view of any adjacent collector or arterial street.
4. Any illumination shall be so arranged as to reflect the light away from adjoining premises and shall be in conformance with CHAPTER 8, ARTICLE 8 of the City Code.